PRIER P-754 provides a year round source of tempered water to areas that are subject to freezing temperatures. The hydrant valve is connected to the supply piping in the heated portion of the structure, eliminating the possibility of freezing. To assure freeze protection, the hydrant will drain even with the hose attached and under pressure.
The integral vacuum breaker/backflow preventer provides protection against cross-contamination with the potable water system, utilizing a double check valve to prevent back pressure and a vacuum breaker to vent in the case of upstream pressure drop. A removable operating key is provided to prevent unauthorized usage of the hydrant. No special installation tools are required.
- Field testable as required by ASSE 1052, pressure rated to 125 PSI, temperature to 140°
- Satin nickel plated body maintains an original finish
- Multiple vent holes ensure proper draining and reduce problems associated with insect nesting
- Patented PRIER “triple seal” positive shutoff system offers triple redundancy to assure shutoff
- High flow rate, 16 gallons per minute at 25 PSI differential
- Same key operates box lock and hydrant
- Heavy pattern cast brass hydrant for use with or without brass box
- Heavy duty brass piping, significantly stronger than ordinary copper tubing, with threaded and sealed joints
- Patented PRIER quick opening and modulating design require less force and fewer turns to operate
- Single control temperature dial
- Simple, robust design and solid temperature control rods for long wear life
- Box design enables valve to be easily secured to any type of inner wall, utilizing integral 3/8”-16 lugs
- 4 mounting holes on valve’s backplate provide for an even and secure installation without a hydrant box
- Check Valves prevent inlet thermal migration
- Maintenance is serviceable from the front of the valve without removing from wall
- PVC pipe included to protect temperature control shaft during installation and from mortar, foam insulation, etc
Publicaciones de blog
-
Cómo localizar válvulas de rociadores ocultas
¿Busca localizar válvulas de rociadores ocultas? Desde sondear el suelo hasta consultar planos, realizar pruebas de clic y utilizar localizadores de cables, brindamos instrucciones paso a paso para encontrar las válvulas de sus aspersores. Dígale adiós a la frustración de las válvulas ocultas y hola a un sistema de rociadores que funcione sin problemas.Leer ahora -
Localizadores de válvulas y cables Armada: su guía esencial
Sumérgete en el mundo de los localizadores de válvulas y cables de Armada para comprender su importancia, características y beneficios. Esta guía proporciona información completa sobre estas herramientas vitales.Leer ahora -
¿Con qué frecuencia debo cambiar el filtro protector del calentador BB-Guard-Filter-3/4 de mi EWS?
Mantener un sistema de calentamiento de agua que funcione correctamente es vital para la comodidad y el bienestar de su hogar. El filtro protector del calentador EWS BB-Guard-Filter-3/4 es un componente clave que ayuda a mantener su calentador de agua funcionando sin problemas.Leer ahora