DryConn Blue/Blue Waterproof Wire Connectors — 100-piece canister
Brand: King Innovation (DryConn)
SKU: 10241
Product Overview
Blue/Blue sealed twist-on connectors are pre-filled with a non-hardening dielectric silicone sealant for outdoor and irrigation wire splices. Choose the 100-piece canister for low-voltage wiring work where a filled connector helps protect the copper connection from water and corrosion. Direct burial is permitted at 30 V or less; consult the ratings below for higher-voltage work in an enclosure.
Key Features
- Silicone-filled, waterproof and corrosion-resistant sealed connector.
- One-step installation without pre-twisting wires.
- UL 486G listed sealed wire connector; made in the USA.
- 100-piece canister of Blue/Blue connectors.
Common Uses
Low-voltage irrigation and landscape-wire splices, including damp, wet and direct-bury applications within the 30 V direct-bury limit.
Technical Specifications
- Conductor material: copper-to-copper, solid and/or stranded combinations.
- Wire range: minimum #22 AWG to maximum #12 AWG; follow the manufacturer's approved wire combinations.
- Building wire rating: 600 V maximum, or 1,000 V maximum for signs or luminaires, when used in an enclosure as specified by the manufacturer.
- Direct bury rating: 30 V maximum.
- Connector temperature rating: 105°C (221°F); silicone sealant range: -45°F to 400°F.
- UL designation: KYN.
Dimensions
Connector size: 17/32 × 15/16 in. Manufacturer drawing measurements: A 0.932 in, B 0.260 in, C 0.539 in, D 0.422 in.
Compatibility & Installation Notes
Turn off power first and follow local and national codes. Strip 3/8 in of insulation, or 7/16 in for #16 AWG and smaller. Hold conductors together, lead stranded wires slightly, then push in and twist clockwise until tight. Do not reuse. For dry, damp or wet above- or below-grade locations at the higher building-wire rating, use an enclosure; direct burial is limited to 30 V or less.
Frequently Asked Questions
Can these connectors be buried directly?
Yes, for direct-bury connections operating at 30 V or less and within the approved wire combinations.
Can they be used on 600 V building wire?
The manufacturer lists 600 V maximum for building wire when the sealed connector is used in an enclosure. That rating does not extend the 30 V direct-bury limit.
Do wires need to be twisted together first?
No. Follow the strip lengths and twist-on installation instructions; do not reuse a removed connector.
Why Buy This Package
The 100-piece canister keeps a larger supply of identical Blue/Blue connectors on hand for repeated irrigation and outdoor wiring work.